Flame Action Control Turn the flame action control knob to adjust the flame speed control to the desired level. Manual Selection Switch Operates the electric fireplace manually. Pressing the switch up (“ “ position) once turns on the electric fireplace and activates Level 1, twice activates Level 2, three times activates Level 3. Pressing the switch down (“ “ position) turns the electric fireplace OFF. Level 1: The flame effect is turned on and the first red indicator light illuminates.

Level 2: The flame effect remains on, the heater is activated to the low heat setting, and the first and second red indicator lights illuminate. Level 3: The flame effect remains on, the heater is set to the high heat setting, and all three red indicators illuminate. Resetting the Temperature Cutoff Switch Should the heater overheat, an automatic cut out will turn the heater off and it will not come back on without being reset.

Dimplex Electric Fireplaces Direct

Owner’s manual • Read online or download PDF • Dimplex DFB6016 User Manual. New Dimplex 26in Electric Fireplace Insert DFB5015 w Trim Kit. Order Availability. Dimplex 26 Manual; Dimplex Green Information; Product Images Return To Top.

It can be reset by switching the Main On/Off Switch to Off and waiting five (5) minutes before switching the unit back on. CAUTION: If you need to continuously reset the heater, unplug the unit and call Dimplex North America Limited at 1-888-346-7539. Remote Control The fireplace is supplied with a radio frequency remote control. This remote control has a range of approximately 50 feet (15.25 m), it does not have to be pointed at the fireplace and can pass through most obstacles (including walls). It is supplied with one of 2,178 independent frequencies to prevent interference with other units.

The frequency designation is indicated on the back of the transmitter. Remote Control Initialization/ Reprogramming Follow steps 1 through 6 to. Ufs Nokia Software. Initialize your fireplace for the first time.

This procedure is also required every time there is a loss of power to the remote control in the fireplace (I.E. Power failure, breaker tripped, main power switch is turned off). Ensure that power is supplied through the main service panel. Access the manual controls, (remove glass doors or pull grill down if applicable) pull the right side steel curtain to the outside of the unit (if applicable). Locate manual controls. Activate main power switch. Press and hold the ON switch marked “ ” for five (5) seconds (red indicator light will flash).

Press the ON button located on the remote control transmitter. This will synchronize the remote control transmitter and receiver.

Agnes Dance Love Pop on this page. Remote Control Usage The remote control operates the fireplace levels sequentially. The level is increased every time the ON button on the transmitter is. Operation three red indicators illuminate. Battery Replacement (Figure 4) To replace the battery: 1.

Slide battery cover open on the hand held transmitter. Correctly install one (1) 12 Volt (A23) battery in the battery holder. Maintenance WARNING: Disconnect power before attempting any maintenance or cleaning to reduce the risk of fire, electric shock or damage to persons. Game Motocross Ps2 For Pc. Light Bulb Replacement Allow at least five (5) minutes for light bulbs to cool off before touching bulbs to avoid accidental burning of skin.

Light bulbs need to be replaced when you notice a dark section of the flame or when the clarity and detail of the log exterior disappears. There are four (4) bulbs under the log set which generate the flames and embers and two (2) bulbs up, in behind the grill that illuminate the interior of the fireplace. Close the battery cover. Battery must be recycled or disposed of properly. Check with your Local Authority or Retailer for recycling advice in your area. Required tools: Phillips #2 screw driver, Slot screw driver. Approximate time: 15 minutes to change upper and lower light bulbs.

Helpful Hints It is a good idea to replace all light bulbs at one time if they are close to the end of their rated life. Group replacement will reduce the number of times you need to open the unit to replace light bulbs. To open the light bulb area: 1. Remove the trim by turning the retaining fasteners counterclockwise 1/4 turn until the trim releases from. The firebox using a slotted screwdriver (Figure 5). Hold the glass in place while removing the retaining clip from the upper center of the firebox (Figure 6A, B). Lift glass out and store in a safe place.

Lower Light Bulb Requirements Quantity of four (4) clear chandelier or candelabra bulbs with an E-12(small) socket base, 60 Watt rating. To replace the bottom light bulbs: 1. Lift up the front edge of the log until it clears the front tabs. Pull out until the rear tab clears the back ledge, then lift out (Figure 7). Upper Light Bulb Requirements Quantity of two (2) clear chandelier or candelabra bulbs with an E-12(small) socket base, 15 Watt rating.